Inputs: BNC connector, Direct wire connection with amplified probe (supports HI 1006 series probes) and 4-20 mA from a transmitter
EC and Resistivity Meter, complete in carrying case. EC 199.9 uS / cm; 1999 uS / cm, 19.99 mS / cm, 199.9 mS / cm M: • Resistance to 19.90 cm.
Multi-Range EC meters with HI 76302W probe. With ATC - Automatic Temperature Compensation. 0.0 to 199.9 mS / cm.
Multi-range hand-TDS meter probe incl HI 76301D, DIN connector, 1 m cable. Ranges: 0.0 to 199.9 mg / L (ppm) 0 to 1999 mg / L (ppm) 0.00 to 19.99 g / L (ppt).
The HI 88703 turbidity benchtop meter is specially designed for water quality measurements, providing reliable and accurate readings on low turbidity ranges.
Table turbidity meter (wide measuring range, several units), ISO 7027, dot matrix LCD, USB
HI8931AN Conductivity Analog Controller with Input from Probe or Transmitter 0.1 mS/cm resolution
All Product
HI8931BN Conductivity Controller (0.01mS/cm resolution) with Input from Probe or Transmitter
HI 8931BN Conductivity Analog Controller with Input from Probe or Transmitter 0.01 mS/cm resolution
Controllers
HI8931CN Conductivity Controller (1 uS/cm resolution) with Input from Probe or Transmitter
HI 8931CN Conductivity Analog Controller with Input from Probe or Transmitter 1 uS/cm resolution
Process controllers
HI8931DN Conductivity Controller (0.1 uS/cm resolution) with Input from Probe or Transmitter
HI 8931DN Conductivity Analog Controller with Input from Probe or Transmitter 0.1 uS/cm resolution
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
HI4016-10 ISE 10 mg/L (ppm) Sodium Std , 500 ml Bottle-Copy
เซ็นเซอร์วัดออกซิเจนในน้ำสำหรับ HI9829 มัลติพารามิเตอร์
HI3833 CTK Phosphate
HI93714-01 Cyanide - Reagents - 100 Tests
HI70030C - EC 12880 µS/cm@25°C Zert. - 25x20ml
เครื่องวัดปริมาณแอมโมเนีย ในน้ำ รุ่น HI715
HI991301 Multiparameter pH/EC/TDS/°C - EC to 20.00 mS
HI70010P - 10.01 pH@25°C - SQ - 25x20ml
HI3815 CTK Chloride
HI7035L - EC 111800 µS/cm@25°C - 500ml
HI5007 - 7.01 pH@25°C - TQ - 500ml
HI721 Checker HC ® - Iron
เครื่องวัดอุณหภูมิอาหาร
HI93719-01 Hardness Magnesium - Reagents -100 Tests
HI70007C - 7.01 pH@25°C - SQ Zert. - 25x20ml
HI7609829-2 - Dissolved Oxygen Sensor for HI9829 Multiparameter
น้ำยามาตรฐานสอบเทียบ ค่ามาตรฐานความเค็ม
HI2111B - pH Half Cell (strong alkaline solution)
เครื่องวัดค่าเหล็ก รุ่น HI721
เครื่องวัดค่ากรด-ด่าง แบบภาคสนาม สำหรับอุตสาหกรรมการชุบ รุ่น HI99131
HI98130 COMBO Tester for pH/EC/TDS/C° up to 20 mS, waterproof
สารละลายมาตรฐานความขุ่น 20 NTU
HI715 Checker HC ® - Ammonia, MR
เครื่องควบคุมค่าความนำไฟฟ้า
Calibration Standard HI 771 Checker HC ®
HI3864 CTK Phenol
เครื่องวัดปริมาณโบรมีน ในตัวอย่างน้ำ รุ่น HI716
เครื่องวัดปริมาณแอมโมเนีย ช่วงสูง รุ่น HI733
HI8733 EC Meter with Multi-Range 0.0 to 199.9 mS/cm ATC 
