Fluoride is one of the very few chemicals that have been shown to cause significant effects in people through drinking-water. Fluoride has beneficial effects on teeth at low concentrations in drinking-water, but excessive exposure to fluoride in drinking-water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.
Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities.
A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.
The HI 729 Checker®HC is simple to use. For this measurement you need 2 vials (#1 and #2); in both vials add 2 mL of reagent and until the mark: deionized water in vial #1 and sample in vial #2, and gently invert 5 times, and wait 2 minutes. Then insert the cuvette #1 into the HI 729 Checker®HC and press the button to zero; after that cuvette #2 to read the measurement results.
Manual: Download
Specification :
| Range | 0.00 to 2.00 ppm | |
| Resolution | 0.01 ppm | |
| Accuracy @ 20°C | ±0.10 ppm ±5% of reading | |
| Light Source | LED @ 575 nm | |
| Light Detector | silicon photocell | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
| Battery Type | (1) 1.5V AAA | |
| Auto-off | after two minutes of non-use and ten seconds after reading | |
| Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) | |
| Weight | 64 g (2.25 oz.) | |
| Method | adaptation of SPADNS method |
HI9828-25 - Quick Calibration Solution, 500 mL
HI3810 CTK Dissolved Oxygen
HI733 Checker HC ® - Ammonia, HR
BL983329-1 TDS Mini Controller 0.0 to 999 mg/L (ppm) - 230V
HI4005-53 Carbon Dioxide membrane kit (3 caps)
HI991300 Multiparameter pH/EC/TDS/°C - EC to 3999 µS
BL983318-1 TDS Mini Controller 0.0 to 10.00 g/L (ppt) - 230V
HI98309 UPW - Ultra Pure Water Tester - Conductivity (up to 1.999 µS/cm)
เครื่องวัดปริมาณฟอสฟอรัส ช่วงต่ำมาก รุ่น HI736
HI7006/1G - 6.86 pH@25°C - SQ - 3.78L
เครื่องวัดปริมาณโบรมีน ในตัวอย่างน้ำ รุ่น HI716
HI715 Checker HC ® - Ammonia, MR
เครื่องวัดปริมาณซิลิกา ช่วงต่ำ ในตัวอย่างน้ำ รุ่น HI705
น้ำยามาตรฐานสอบเทียบ
Reagents for HI 755 Checker HC ®, 25 Tests 