Bromine, because it is stable and less volatile than chlorine, is utilized as a disinfectant in swimming pools, spas and hot tubs. As with chlorine, excessive quantities of bromine in water can be dangerous to health and can cause eye irritation.
Daily monitoring of bromine concentration prevents damage to equipment and contributes to the optimization and efficiency of the process while providing for increased user safety.
The HANNA portable bromine test kit determines the bromine level in water with efficiency. The first step involves pH adjustment of the sample to pH 6.3 by adding pH buffer. The second step consists of adding the second reagent, an indicator solution which contains DPD (N, N-diethyl-p-phenylenediamine). DPD is immediately oxidized by bromine producing a reddish color. The color intensity of the solution determines the bromine concentration.
Order Information:
HI 3830 test kit comes with 30 mL reagent 1, 20 mL reagent 2, color comparison cube, and plastic vessel.
Manual: Download
Specification :
| Method | Colorimetric | |
| Range | 0.0-3.0 mg/L | |
| Smallest Increment | 0.6 mg/L | |
| Chemical Method | DPD | |
| Number of Tests | approx. 60 | |
| Weight | 370 g |
เครื่องควบคุมค่าความนำไฟฟ้า
HI8410 Dissolved Oxygen Controller with 4 to 20mA
HI7031L - EC 1413 µS/cm@25°C - 500ml
HI3190T -Redox Electrode Industry
เครื่องวัดปริมาณอัลคาไลนิตี้ (dKH) ในน้ำทะเล รุ่น HI772
Reagents for Freshwater Alkalinity HI 775 Checker HC ®, 25 Tests
HI3873 CTK Nitrite
Reagents for HI 713 Checker HC ®, 25 Tests
HI6100205 - AmpHel Flat Tip (Acid with Fluoride ions) Process pH Electrode
HI93703-05 AMCO-AEPA-1 Calibration Solution at 500 FTU, 30 ml-Copy
HI7609829-4 - Conductivity / Turbidity Sensor for HI9829 Multiparameter
HI7036L - 12.41 g/L (ppt) TDS @25°C - 500ml
HI145-00 Thermometer (°C) with T-shaped (125mm)
HI7006L - 6.86 pH@25°C - SQ - 500ml
HI4004-01 ISE 0.1M Calcium Std , 500 ml Bottle
HI7078 Electrolyte solution 4 x 30 ml
HI4016-02 ISE 100 mg/L (ppm) Sodium Std , 500 ml Bottle
HI7075 Electrode filling solution 1.7M KNO3 + 0.7M KCl, 4 x 30 ml
HI70442L - 1500 mg/L (ppm) TDS @25°C - 500ml
Multiparameter pH/ORP/EC/Pressure/Temperature Waterproof Meter
Reagents for HI 708 Checker HC ®, 25 Tests
HI763100 Digital conductivity electrode - 4 ring, platinum (edge)
HI38067-100 - Reagents for CTK Silica HR
HI3864 CTK Phenol
HI93712-01 Aluminium - Reagents - 100 Tests
HI10530 Digital pH-Electrode, Conical Tip, Glass, Refillable (edge)
HI70004P - 4.01 pH@25°C - SQ - 25x20ml
Reagents for HI 755 Checker HC ®, 25 Tests
HI7034L - EC 80000 µS/cm@25°C - 500ml
HI700661P - RfE - Landwirtschaft - 25x20ml
HI4108 - Feststoffelektrode, kombiniert
HI3818 CTK Carbon Dioxide
HI93706-01 Phosphorous - Reagents - 100 Tests 

