Dual-Channel Universal Process Controller for Industrial – HI520
HI520 is an advanced process controller that can be configured for applications requiring monitoring and/or control of four main water-analysis parameters: pH, ORP, Conductivity, and Dissolved Oxygen.
– Waterproof IP65 (Nema 4X) enclosure
– Multi-color LED status indicators & audible alarm
– Universal mounting kits available with wall, pipe, and panel mounting options (All mounting kits must be ordered separately.)
HI520 is an advanced process controller that can be configured for applications requiring monitoring and/or control of four main water-analysis parameters: pH, ORP, Conductivity, and Dissolved Oxygen. This controller features a digital probe input(s) that automatically detects and updates the controller with the parameter that it measures.
HI520 is Hanna’s first dual-input process controller that accepts virtually any combination of compatible probes. Designed to adapt to unique process control requirements, users have the option to enable or disable each channel independently.
Additionally, HI520 introduces enhanced industrial control by operating a control-loop system whereby users have the option to run channel control either independently or configure to be triggered sequentially upon reaching the other channel’s set point(s) (1, 2, or both). The device operates a logical channel with built-in mathematical functions. This function is intended for when the controller works as an analyzer for monitoring high/low parameter levels between two identical inputs with identical measuring configurations.

Set points for control operations can be configured to be on/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.
Hold can also be triggered manually and by using and external digital input for disabling control mode when performing maintenance.
Configurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.
The cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.

Relays
Available with up to five control and one alarm electromechanical relays.
Analog Outputs
Up to four galvanically isolated analog outputs for control of pumps and valves.
Digital RS485 Output
Can daisy-chain up to 32 devices to a remote monitoring system.
Digital Inputs
Two digital inputs available for modes including disabling, cleaning and placing the controller into hold status.
Manual : Downloads
Specification :
| SKU | HI520 |
| Product Name | Dual-Channel Universal Process Controller for Industrial Applications – HI520 |
| Channels | 2 |
| Display | Graphic LCD, 128 x 64 pixel B/W with backlight |
| Digital Inputs | 2 independent, galvanically isolated inputs (configurable for Hold & Cleaning functions) |
| On state | 5 to 24 Vdc, low or high level active |
| Analog Outputs | 2 or 4 independent, galvanically isolated outputs 0 – 22 mA configurable as |
| Digital Communication | RS485 serial port – Remote monitoring and control USB-C port – Retrieve log files and firmware upgrading |
| Relays | Up to 5 relays (independently configurable for process variables, Hold & Cleaning functions |
| Fuse protected | 5A, 250V slow blow fuse |
| Alarm Relay for All Measurement Alarms | Electromechanical relay SPDT contact output 5A – 250 Vac; 5A – 30 Vdc (resistive load) Fuse protected |
| Data Logging | Interval log, up to 100 files, maximum 8600 records on each stored file. When the maximum limit of 100 stored files is reached, the most recent file will automatically erase the oldest one. |
| Power Supply | 100 – 240 Vac ±10%; 50/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse) |
| Power Consumption | 15VA |
| Installation Category | II |
| Environment | -20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing |
| Enclosure* | Single case ½ DIN, type 4X, IP65 ingress protection |
| Weight | Approximately 1.6 kg |
HI1043B - pH Electrode for high temperature & strong acid
เครื่องวัดปริมาณคลอรีนอิสระ รุ่น HI701
ชุดทดสอบวัดค่าเหล็ก (HI3834)
เครื่องวัดปริมาณฟอสฟอรัส ช่วงต่ำมาก รุ่น HI736
เครื่องวัดสีในน้ำตัวอย่าง HI727
HI70000P - RfE - Standard Anwendung - 25x20ml
สารละลายมาตรฐานสำหรับสอบเทียบค่ากรด-ด่าง 7.01 (HI7007/1G)
HI76409A/P DO Membrane for probe HI 76409 (5 pcs)
เครื่องวัดคลอรีน
HI70442L - 1500 mg/L (ppm) TDS @25°C - 500ml
Reagents for HI 736 Checker HC ®, 25 Tests
HI5074 - 7.40 pH@25°C - TQ - 500ml
HI8931CN Conductivity Controller (1 uS/cm resolution) with Input from Probe or Transmitter
เครื่องวัดปริมาณโบรมีน ในตัวอย่างน้ำ รุ่น HI716
HI76407A/P DO Membrane for probe HI 76407 (5 pcss)
HI768L Pt100-Type, 4-Wire Air /Liquid
FC300B Sodium ISE
CTK Chlor Gesamt HI38023
CTK Chlor Frei
เครื่องวัดปริมาณแอมโมเนีย ช่วงสูง รุ่น HI733
Reagents for HI 770 Checker HC ®, 25 Tests
HI70480 Free-chlorine reagent kit for PCA Series
HI62911D - pH/°C Electrode
HI7035L - EC 111800 µS/cm@25°C - 500ml
เครื่องวัดปริมาณโครเมี่ยม ช่วงสูง รุ่น HI723
เครื่องวัดปริมาณไนเตรตในน้ำทะเลช่วงต่ำ รุ่น HI781
HI93712-01 Aluminium - Reagents - 100 Tests 