Silica is the name given to silicon dioxide, SiO2. Silicon, Si, is the most abundant element in the Earth’s crust, 28% of it by weight. Silicon is never found free form in nature. In crystallized form it is only reactive under conditions of extremely high temperatures. Water and water vapor probably have little influence upon silicon solubility, because a protective surface layer of silicon dioxide is rapidly formed. Silicon binds with other elements to form various species of silica and silicate. The concentration of the soluble silica molecules are important to aquaculture because they influence (and limit) the growth of diatoms. In most waters, the predominant form of dissolved silica is monosilicic acid, which incorporates 2 water molecules.
The HANNA HI 770 Checker®HC is accurate and affordable. This portable handheld colorimeter features a resolution of 1 ppm (200 points) and ±2 ppm ±5% of reading accuracy.
The contoured style of the HI 770 Checker®HC fit in your palm and pocket perfectly and the large LCD is easy to read. The auto shut off feature assures the battery life will not be drained if you forget to turn it off.
The HI 770 Checker®HC is simple to use. First, zero the instrument with your water sample. Next, add the reagents in order, respecting all the indications. Last, place the vial into the Checker®HC, press the operational button for about 3 seconds and the display will show the countdown prior to the measurement or, alternatively, wait for 2 minutes after last reagent adding and press operational button. The Checker®HC displays concentration in ppm of Silica as SiO2.
Order Information: HI 770 Checker®HC is supplied with sample cuvettes with caps (2 ea.), powder reagents for 6 tests, battery and instructions.
Manual: Download
Specification :
| Range | 0 to 200 ppm | |
| Resolution | 1 ppm | |
| Accuracy @ 20°C | ±2 ppm ±5% of reading | |
| Light Source | LED @ 470 nm | |
| Light Detector | silicon photocell | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
| Battery Type | 1.5V AAA | |
| Auto-off | after two minutes of non-use | |
| Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) | |
| Weight | 64 g (2.25 oz.) | |
| Method | adaptation of the USEPA METHOD 370.1 for drinking, surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO2 C |
HI7072 Electrolyte Solution, 1M KNO³, 4 x 30 ml
เครื่องวัดปริมาณฟอสเฟต ช่วงสูง รุ่น HI717
HI99301 EC / TDS / °C Meter upto 20 mS
HI3833 CTK Phosphate
น้ำยามาตรฐานสอบเทียบ ค่ามาตรฐานความเค็ม
HI70032P - 1382 mg/l (ppm) TDS@25°C - 25x20ml
HI7032L - 1382 mg/L (ppm) TDS @25°C - 500ml
HI731331 - Glass Cuvette 4 pcs. - Serie HI967xx & HI93414 & HI98703
HI6007-01 - 7.010 pH@25°C - MQ - 1000ml
HI7039L - EC 5000 µS/cm@25°C - 500ml
HI9812-5 Multiparameter pH/EC/TDS/°C - EC to1990 µS/cm
HI931001 pH and mV Precision Simulator (BNC)
เครื่องควบคุมค่าความนำไฟฟ้า 