Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Transmitter
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Process controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
The conductivity transmitter Type HI 8936 has been redesigned and now uses a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. In addition, the integrated temperature sensor compensates the transmitter on the probe temperature-dependent effects. The probe is connected via a positive electrical connection to signal losses to avoid long lines. All this increases the power of the transmitter which significantly represent the HI 8936 devices in any position until a classic piece.
Controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Potentiometric titrators
HI902C2 – Titration System – Potentiometric – 2 analog boards
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Automatic Titrators
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms.
Multi-Range EC meters with HI 76302W probe, waterproof. With ATC - Automatic Temperature Compensation. 0.0 to 199.9 mS / cm.
Multi-range hand-TDS meter incl HI 76302W probe, DIN connector, 1 m cable. ATC - Automatic Temperature Compensation. Ranges: 0.0 to 199.9 mg / L (ppm) 0 to 1999 mg / L (ppm) 0.00 to 19.99 g / L (ppt).
Coulometric titrator
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
Automatic Titrators
HI904D Karl Fischer Coulometric Titrator with Diaphragm Generator – 1ppm to 5%
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
Reagents for Freshwater Alkalinity HI 775 Checker HC ®, 25 Tests
HI3835 CTK Salinity
HI38001-10 - Reagents for CTK Sulfate LR / HR
สารละลายมาตรฐานสำหรับสอบเทียบความเค็ม แบบซอง HI70024P
HI93706-01 Phosphorous - Reagents - 100 Tests
HI7035L - EC 111800 µS/cm@25°C - 500ml
HI766F1 K-Type, Wire Probe
น้ำยามาตรฐานสอบเทียบ ค่ามาตรฐานความเค็ม
HI5006 - 6.00 pH@25°C - TQ - 500ml
HI904D Karl Fischer Coulometric Titrator with Diaphragm Generator - 1ppm to 5%
HI920005 i-Button® tags (tag identification system) (5 pcs)
HI708 Checker HC ® - Nitrite, HR
HI96740-11 CalCheck ™ Nickel LR Calibration-Set
HI740217 Lab Safety Shield for COD Measurement
บีกเกอร์พลาสติก ขนาด 170 ml จำนวน 6 ชิ้น (HI740224)
HI8733 EC Meter with Multi-Range 0.0 to 199.9 mS/cm ATC
BL983329-1 TDS Mini Controller 0.0 to 999 mg/L (ppm) - 230V
เซ็นเซอร์วัดออกซิเจนในน้ำสำหรับ HI9829 มัลติพารามิเตอร์
HI11310 Digital pH-Electrode, Glass, refillable (edge)
HI93719-01 Hardness Magnesium - Reagents -100 Tests
HI731335 - Cap for Cuvette 4 pcs. - Serie HI967xx
เครื่องวัดสีในน้ำตัวอย่าง HI727
HI70030C - EC 12880 µS/cm@25°C Zert. - 25x20ml
Reagents for HI 715 Checker HC ®, 25 Tests
HI38020 CTK Chlorine Free & Total
HI7635 - Industrial Conductivity Probe
เครื่องวัดปริมาณคลอรีนรวม รุ่น HI711
HI70480 Free-chlorine reagent kit for PCA Series
HI96711-11 CalCheck ™ Chlorine Total Calibration-Set
HI7031L - EC 1413 µS/cm@25°C - 500ml
เครื่องวัดค่าการนำไฟฟ้า สำหรับน้ำบริสุทธิ์สูง (UPW) รุ่น HI98309
HI3833 CTK Phosphate
HI70009P - 9.18 pH@25°C - SQ - 25x20ml
HI2008 - ORP Electrode for PCA
HI93714-01 Cyanide - Reagents - 100 Tests
HI98304 DiST®4 EC-Tester (up to 19.99 mS)
HI3831T CTK Chlorine Total
HI3190T -Redox Electrode Industry
HI7009L - 9.18 pH@25°C - SQ - 500ml
HI2004 - edge® Dedicated Dissolved Oxygen Meter
HI70442L - 1500 mg/L (ppm) TDS @25°C - 500ml
HI4014-00 ISA for Potassium ISE's
HI935005 K-Type Handheld-Thermometer - 1-Channel