Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Process controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
The conductivity transmitter Type HI 8936 has been redesigned and now uses a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. In addition, the integrated temperature sensor compensates the transmitter on the probe temperature-dependent effects. The probe is connected via a positive electrical connection to signal losses to avoid long lines. All this increases the power of the transmitter which significantly represent the HI 8936 devices in any position until a classic piece.
Controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Potentiometric titrators
HI902C2 – Titration System – Potentiometric – 2 analog boards
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Automatic Titrators
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms.
Multi-Range EC meters with HI 76302W probe, waterproof. With ATC - Automatic Temperature Compensation. 0.0 to 199.9 mS / cm.
Multi-range hand-TDS meter incl HI 76302W probe, DIN connector, 1 m cable. ATC - Automatic Temperature Compensation. Ranges: 0.0 to 199.9 mg / L (ppm) 0 to 1999 mg / L (ppm) 0.00 to 19.99 g / L (ppt).
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
Coulometric titrator
HI904D Karl Fischer Coulometric Titrator with Diaphragm Generator – 1ppm to 5%
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
HI145-00 Thermometer (°C) with T-shaped (125mm)
HI4013-03 ISE 1000 mg/L (ppm) Nitrate Std , 500 ml Bottle
HI4016-03 ISE 1000 mg/L (ppm) Sodium Std , 500 ml Bottle
HI70007P - 7.01 pH@25°C - SQ - 25x20ml
HI93732-01 Dissolved Oxygen - Reagents - 100 Tests
HI7036L - 12.41 g/L (ppt) TDS @25°C - 500ml
HI70032C - 1382 mg/l (ppm) TDS@25°C Cert. - 25x20ml
HI70080C - 800 mg/l (ppm) TDS@25°C Zert. - 25x20ml
HI726 Checker HC ® - Nickel, HR
เครื่องวัดคลอรีน
HI98183 pH / ORP / °C Meter + PC Interface, Waterproof
HI3812-100 - Reagents for CTK Härdness Total
HI713 Checker HC ® - Phosphate, LR
HI3002 - Submersion Conductivity Process Probe
น้ำยามาตรฐานสอบเทียบ
Chlor Frei - Reagenzien-Kit - 100 Tests
เครื่องวัดปริมาณโบรมีน ในตัวอย่างน้ำ รุ่น HI716
เครื่องวัดปริมาณฟอสเฟต ช่วงสูง รุ่น HI717
HI5007 - 7.01 pH@25°C - TQ - 500ml
เครื่องวัดปริมาณซิลิกา ช่วงต่ำ ในตัวอย่างน้ำ รุ่น HI705
เครื่องวัดปริมาณแอมโมเนีย ในน้ำ รุ่น HI715
HI38058 CTK pH
HI7078 Electrolyte solution 4 x 30 ml
HI3818 CTK Carbon Dioxide
HI920005 i-Button® tags (tag identification system) (5 pcs)
HI4104 - Calcium ISE, Polymer membrane combination
HI4013-01 ISE 0.1M Nitrate Std , 500 ml Bottle
HI1001 Industrial-pH-Electrode "Flow-thru" Monitoring, PVDF BNC, 3 m Cable
HI7010L - 10.01 pH@25°C - SQ - 500ml
HI70480 Free-chlorine reagent kit for PCA Series
CTK Härte Gesamt
HI7609829-2 - Dissolved Oxygen Sensor for HI9829 Multiparameter
Reagents for Freshwater Alkalinity HI 775 Checker HC ®, 25 Tests
HI8931BN Conductivity Controller (0.01mS/cm resolution) with Input from Probe or Transmitter
HI9812-5 Multiparameter pH/EC/TDS/°C - EC to1990 µS/cm
HI7635 - Industrial Conductivity Probe
HI766E1 K-Type, General Purpose w Cable
HI710006 Power Adapter, 230 Vac to 12 VDC, European Plug
HI93750-01 Potassium - Reagents - 100 Tests
HI935005 K-Type Handheld-Thermometer - 1-Channel
HI93721-01 Iron HR - Reagents -100 Tests
HI93714-01 Cyanide - Reagents - 100 Tests
HI904 Karl Fischer Coulometric Titrator - 1ppm to 5%