Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Process controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
All Product
The conductivity transmitter Type HI 8936 has been redesigned and now uses a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. In addition, the integrated temperature sensor compensates the transmitter on the probe temperature-dependent effects. The probe is connected via a positive electrical connection to signal losses to avoid long lines. All this increases the power of the transmitter which significantly represent the HI 8936 devices in any position until a classic piece.
Controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Potentiometric titrators
HI902C1 – Titration System – Potentiometric – 1 analog board
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Potentiometric titrators
HI902C2 – Titration System – Potentiometric – 2 analog boards
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Automatic Titrators
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms.
Multi-Range EC meters with HI 76302W probe, waterproof. With ATC - Automatic Temperature Compensation. 0.0 to 199.9 mS / cm.
Multi-range hand-TDS meter incl HI 76302W probe, DIN connector, 1 m cable. ATC - Automatic Temperature Compensation. Ranges: 0.0 to 199.9 mg / L (ppm) 0 to 1999 mg / L (ppm) 0.00 to 19.99 g / L (ppt).
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
Coulometric titrator
HI904D Karl Fischer Coulometric Titrator with Diaphragm Generator – 1ppm to 5%
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
HI7091L - Reducing Pretreatment Solution, 500 ml
Multiparameter pH/ORP/EC/Pressure/Temperature Waterproof Meter
HI7075 Electrode filling solution 1.7M KNO3 + 0.7M KCl, 4 x 30 ml
HI4007-02 ISE 100 mg/L (ppm) Chloride Std , 500 ml Bottle
HI98312 DiST®6 EC/TDS/C°-Tester, (0.00-20.00 mS/cm - 0.00-10.00 g/l (ppt)) waterproof
Reagents for HI 758 Checker HC ®, 25 Tests
HI38058-100 - Reagents for CTK pH
HI7021L - 240mV ORP Test Solution - 500ml
HI93703C Turbidity Meter ISO 7027 with Calibration Standard & Casing
HI95747-01 Copper LR - Reagents - 100 Tests
HI740217 Lab Safety Shield for COD Measurement
Reagents for HI 701 (Free Chlorine), 25 Tests
HI38039-100 - Reagents for CTK Iron LR
HI7071 Electrolyte Solution 3.5 M KCl + AgCl, 4 x 30 ml
HI93531 K-Type 1-Channel Handheld-Thermometer
HI93723-01 Chromium VI HR - Reagents - 100 Tests
HI931001 pH and mV Precision Simulator (BNC)
เครื่องควบคุมค่าความนำไฟฟ้า
HI93710-01 pH photometric - Reagents- 100 Tests
HI7035L - EC 111800 µS/cm@25°C - 500ml
HI5011 - 11.00 pH@25°C - TQ - 500ml
HI7078 Electrolyte solution 4 x 30 ml
HI766E1 K-Type, General Purpose w Cable
HI4014-01 0.1 M Potassium Standard
HI93717-01 Phosphate HR - Reagents - 100 Tests
หัววัดค่าการนำไฟฟ้า/ของแข็งที่ละลายในน้ำ แบบ Four ring รุ่น HI76313 (Platinum)
HI7031L - EC 1413 µS/cm@25°C - 500ml
HI7009L - 9.18 pH@25°C - SQ - 500ml
Reagents for HI 758 Checker HC ®, 25 Tests
HI4013-06 Nitrate Interferent Suppressant ISA, 500 ml Bottle
HI6200405 - AmpHel Process ORP Electrode
HI7074L - RfE - Anorganische Substanzen - 500ml
HI7639 - Inline Conductivity Probes with Platium Ring with PT100 sensor
HI7077L - Oil and Fats - 500ml
HI904 Karl Fischer Coulometric Titrator - 1ppm to 5%