Process controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Controllers
The conductivity transmitter Type HI 8936 has been redesigned and now uses a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. In addition, the integrated temperature sensor compensates the transmitter on the probe temperature-dependent effects. The probe is connected via a positive electrical connection to signal losses to avoid long lines. All this increases the power of the transmitter which significantly represent the HI 8936 devices in any position until a classic piece.
All Product
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Automatic Titrators
HI902C1 – Titration System – Potentiometric – 1 analog board
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Potentiometric titrators
HI902C2 – Titration System – Potentiometric – 2 analog boards
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Volumetric titrator
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms.
Multi-Range EC meters with HI 76302W probe, waterproof. With ATC - Automatic Temperature Compensation. 0.0 to 199.9 mS / cm.
Multi-range hand-TDS meter incl HI 76302W probe, DIN connector, 1 m cable. ATC - Automatic Temperature Compensation. Ranges: 0.0 to 199.9 mg / L (ppm) 0 to 1999 mg / L (ppm) 0.00 to 19.99 g / L (ppt).
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
Coulometric titrator
HI904D Karl Fischer Coulometric Titrator with Diaphragm Generator – 1ppm to 5%
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
HI1143B - Electrode (Fluoride Application)
BL983313-1 EC Mini Controller, 0 to 1999 µS/cm, 230V
สารละลายมาตรฐานสำหรับสอบเทียบค่ากรด-ด่าง pH 4.01 (HI7004L)
HI6010-01 - 10.010 pH@25°C - MQ - 1000ml
HI7090L ISA solution for Sodium ISE, 500 ml Bottle
HI93703-05 AMCO-AEPA-1 Calibration Solution at 500 FTU, 30 ml-Copy
เครื่องวัดค่ากรด-ด่าง/คลอรีน/อุณหภูมิ แบบต่อเนื่อง รุ่น PCA320
HI766TR1 K-Type, Long Penetration Probe
HI70004C - 4.01 pH@25°C - SQ Zert. - 25x20ml
HI98303 DiST®3 EC-Tester (up to 1999 µS)
HI3873 CTK Nitrite
HI8410 Dissolved Oxygen Controller with 4 to 20mA
HI93757-01 Ozone - Reagents - 100 Tests
HI3131B - Refillable Combination ORP Electrode for Titration and Laboratory Use
Reagents for HI 707 Checker HC ®, 25 Tests
HI7030L - EC 12880 µS/cm@25°C - 500ml
HI1001 Industrial-pH-Electrode "Flow-thru" Monitoring, PVDF BNC, 3 m Cable
HI7001L - 1.68 pH@25°C - SQ - 500ml
HI70670L - RfE - Salzablagerungen - 500ml
HI93734-01 Chlorine HR Free & Total - Reagents - 100 Tests
HI93750-01 Potassium - Reagents - 100 Tests
เครื่องวัดปริมาณคลอรีนอิสระ รุ่น HI701
HI3002 - Submersion Conductivity Process Probe
HI7078 Electrolyte solution 4 x 30 ml
HI93710-01 pH photometric - Reagents- 100 Tests
HI904 Karl Fischer Coulometric Titrator - 1ppm to 5%