Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Process controllers
The conductivity transmitter Type HI 8936 has been redesigned and now uses a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. In addition, the integrated temperature sensor compensates the transmitter on the probe temperature-dependent effects. The probe is connected via a positive electrical connection to signal losses to avoid long lines. All this increases the power of the transmitter which significantly represent the HI 8936 devices in any position until a classic piece.
Controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Automatic Titrators
HI902C1 – Titration System – Potentiometric – 1 analog board
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Potentiometric titrators
HI902C2 – Titration System – Potentiometric – 2 analog boards
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Volumetric titrator
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms.
Multi-Range EC meters with HI 76302W probe, waterproof. With ATC - Automatic Temperature Compensation. 0.0 to 199.9 mS / cm.
Multi-range hand-TDS meter incl HI 76302W probe, DIN connector, 1 m cable. ATC - Automatic Temperature Compensation. Ranges: 0.0 to 199.9 mg / L (ppm) 0 to 1999 mg / L (ppm) 0.00 to 19.99 g / L (ppt).
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
Coulometric titrator
HI904D Karl Fischer Coulometric Titrator with Diaphragm Generator – 1ppm to 5%
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
BL983315-1 TDS Mini Controller 0.0 to 199.9 mg/L (ppm) - 230V
HI7082 Electrolyte Solution 3.5M KCL, 4 x 30 ml
HI713 Checker HC ® - Phosphate, LR
HI98308 PWT - Pure Water Tester - Conductivity (up to 99.99 µS/cm)
HI5011 - 11.00 pH@25°C - TQ - 500ml
HI766TR1 K-Type, Long Penetration Probe
HI2020 edge™ - pH Meter
BL982411-1 ORP Mini Controller upto 1000mV - 230V
HI721 Checker HC ® - Iron
HI991300 Multiparameter pH/EC/TDS/°C - EC to 3999 µS
HI7001L - 1.68 pH@25°C - SQ - 500ml
HI775 Checker HC ® - Alkalinity in fresh water (dKH)
HI98130 COMBO Tester for pH/EC/TDS/C° up to 20 mS, waterproof
HI931002 4-20mA Amperometer, Simulator and Calibrator
BL983322-1 EC Mini Controller, 0 to 19.99 µS/cm, 230V
HI710006 Power Adapter, 230 Vac to 12 VDC, European Plug
HI93703C Turbidity Meter ISO 7027 with Calibration Standard & Casing
Turbidity (EPA method) and Chlorine Portable Meter - HI93414
BL983320-1 EC Mini Controller 0 to 199.9 µS/cm, 230V
HI904 Karl Fischer Coulometric Titrator - 1ppm to 5%