Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Transmitter
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Process controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
All Product
The conductivity transmitter Type HI 8936 has been redesigned and now uses a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. In addition, the integrated temperature sensor compensates the transmitter on the probe temperature-dependent effects. The probe is connected via a positive electrical connection to signal losses to avoid long lines. All this increases the power of the transmitter which significantly represent the HI 8936 devices in any position until a classic piece.
All Product
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Automatic Titrators
HI902C1 – Titration System – Potentiometric – 1 analog board
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Potentiometric titrators
HI902C2 – Titration System – Potentiometric – 2 analog boards
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Automatic Titrators
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms.
Multi-Range EC meters with HI 76302W probe, waterproof. With ATC - Automatic Temperature Compensation. 0.0 to 199.9 mS / cm.
Multi-range hand-TDS meter incl HI 76302W probe, DIN connector, 1 m cable. ATC - Automatic Temperature Compensation. Ranges: 0.0 to 199.9 mg / L (ppm) 0 to 1999 mg / L (ppm) 0.00 to 19.99 g / L (ppt).
Coulometric titrator
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
Coulometric titrator
HI904D Karl Fischer Coulometric Titrator with Diaphragm Generator – 1ppm to 5%
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
HI5005 - 5.00 pH@25°C - TQ - 500ml
HI3314 - Resistivity Probe for BL983314 Mini Controller
HI93751-01 Sulfate - Reagents - 100 Tests
CTK Härte Gesamt
HI4013-06 Nitrate Interferent Suppressant ISA, 500 ml Bottle
Reagents for HI 723 Checker HC ®, 25 Tests
HI768L Pt100-Type, 4-Wire Air /Liquid
สารละลาย ISA สำหรับวัดค่าไอออนโซเดียม (HI7090L)
HI7004L - 4.01 pH@25°C - SQ - 500ml
HI5001 - 1.00 pH@25°C - TQ - 500ml
HI903 Karl Fischer Volumetric Titrator - 100ppm to 100%
HI4010-03 ISE 1000 mg/L (ppm) Fluoride Std , 500 ml Bottle
HI98304 DiST®4 EC-Tester (up to 19.99 mS)
HI76301D Four ring Conductivity probe
HI755-26
HI739 Checker HC ® - Fluoride. HR
HI7035L - EC 111800 µS/cm@25°C - 500ml
HI96734-11 CalCheck ™ Chlorine HR Free & Total Calibration-Set
HI4016-10 ISE 10 mg/L (ppm) Sodium Std , 500 ml Bottle-Copy
หัววัดค่ากรด-ด่าง แบบดิจิตอล รุ่น HI12300 ใช้งานสำหรับภาคสนาม
Reagents for HI 764 Checker HC ®, 25 Tests
HI98128 pH/°C-Tester (0.01 pH resolution) - waterproof
HI7039L - EC 5000 µS/cm@25°C - 500ml
HI8936DN EC - Transmitter - 0.0 to 199.9 µS/cm