Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
Process controllers
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe- is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
All Product
The conductivity transmitter Type HI 8936 has been redesigned and now uses a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. In addition, the integrated temperature sensor compensates the transmitter on the probe temperature-dependent effects. The probe is connected via a positive electrical connection to signal losses to avoid long lines. All this increases the power of the transmitter which significantly represent the HI 8936 devices in any position until a classic piece.
Transmitter
Conductivity Process Controller & Transmitter type HI 8936 uses a four-ring potentiometric probe-Sonde.Diese is virtually immune to contamination by unclean solutions. Moreover, the compensated, in the probe, simplified integrated temperature sensor and provides automatic compensation. The probe is connected to a positive electrical connection to signal loss to avoid long lines and to increase the performance of the controller.
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Potentiometric titrators
HI902C2 – Titration System – Potentiometric – 2 analog boards
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
Automatic Titrators
The HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms.
Multi-Range EC meters with HI 76302W probe, waterproof. With ATC - Automatic Temperature Compensation. 0.0 to 199.9 mS / cm.
Multi-range hand-TDS meter incl HI 76302W probe, DIN connector, 1 m cable. ATC - Automatic Temperature Compensation. Ranges: 0.0 to 199.9 mg / L (ppm) 0 to 1999 mg / L (ppm) 0.00 to 19.99 g / L (ppt).
Coulometric titrator
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
Coulometric titrator
HI904D Karl Fischer Coulometric Titrator with Diaphragm Generator – 1ppm to 5%
The HI 904 excels at determining water content in extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
HI7031L - EC 1413 µS/cm@25°C - 500ml
HI4010-00 TISAB II for Fluoride ISE, 500 ml Bottle
สารละลายมาตรฐานความขุ่น 20 NTU
ชั้นวางหลอดทดลองระบายความร้อนทำจากสแตนเลสสตีล (HI740216)
หัววัดอุณหภูมิ รุ่น HI7662
เครื่องวัดปริมาณฟอสฟอรัส ช่วงต่ำมาก รุ่น HI736
HI5006 - 6.00 pH@25°C - TQ - 500ml
HI93733-01 Ammonia HR - Reagents - 100 Tests
HI70007C - 7.01 pH@25°C - SQ Zert. - 25x20ml
สารละลายมาตรฐานสำหรับสอบเทียบค่ากรด-ด่าง 7.01 (HI7007/1G)
เครื่องวัดค่ากรด-ด่าง แบบภาคสนาม สำหรับเนื้อสัตว์ รุ่น HI99163
HI38061 CTK Phosphate
Reagents for HI 705 Checker HC ®, 25 Tests
HI731325W - Cap for Cuvette 4 pcs. - Serie HI832xx
HI7639 - Inline Conductivity Probes with Platium Ring with PT100 sensor
HI93732-01 Dissolved Oxygen - Reagents - 100 Tests
HI93717-01 Phosphate HR - Reagents - 100 Tests
HI5002 - 2.00 pH@25°C - TQ - 500ml
HI93746-01 Iron LR - Reagents -100 Tests
HI8936CN EC - Transmitter - 0 to 1999 µS/cm