- pH Calibration Check™
- Five point pH calibration with seven standard and five custom pH buffers
- Log on demand (500 samples)
- User-selectable “calibration time out”
- Tutorial messages on LCD
- PC interface via USB
HI 98172 is a pH/ORP/ISE meter housed in a waterproof casing. Up to five point pH calibration is available with seven memorized pH buffers and five custom pH buffers to provide users with the flexibility necessary to adjust the calibration range to obtain the most accurate and precise readings.
Exchange out the pH sensor for an ORP sensor to obtain mV readings. ISE sensors are calibrated up to five points and measurements are displayed in ppm.
Calibration Check™ incorporates an electrode condition graph which alerts the user with regards to the electrode status. If readings are taken too far outside the calibration range, the unit will warn the user with a graphic signal. Users may set a reminder to notify when calibration is due.
HI 98172 features tutorial messages on the LCD and an auto-end mode to ensure readings are taken only when they are stable. Comprehensive GLP data are directly accessible by pressing the GLP key and log-on-demand holds up to 500 records. Data can be transferred to a PC via USB with optional HI 92000 software and HI 920014 USB connection cable.
Order Information: HI 98172 is supplied with HI 1230B pH electrode, HI 7662 temperature probe, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, 100 mL plastic beaker, batteries, instructions and hard carrying case.
Manual: Download
Specification :
Range | pH | -4.0 to 20.0 pH; -4.00 to 20.00 pH |
mV | ±699.9; ±2000 mV | |
ISE | 0.001 to 19990 ppm | |
Temperature | -20.0 to 120.0°C (-4.0 to 248.0°F) | |
Resolution | pH | 0.1 pH; 0.01 pH |
mV | 0.1 mV (±699.9 mV); 1 mV (±2000) | |
ISE | 0.001 ppm (0.001 to 1.999); 0.01 ppm (2.00 to 19.99); 0.1 ppm (20.0 to 199.9); 1 ppm (200 to 1999); 10 ppm (2000 to 19990) | |
Temperature | 0.1°C (0.1°F) | |
Accuracy (@20°C/68ºF) | pH | ±0.1 pH; ±0.01 pH |
mV | ±0.2 mV (±699.9 mV); ±1 mV (±2000 mV) | |
ISE | ±0.5% f.s. | |
Temperature | ±0.2°C (±0.4°F) excluding probe error | |
pH Calibration | up to five point calibration with seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and 5 custom buffers | |
ISE Calibration | up to five point calibration with six standard buffers available (0.1, 1, 10, 100, 1000, 10000 ppm) | |
Slope/Offset Calibration | ±1 pH/from 80 to 110% | |
Rel. mV Offset Range | ±2000 mV | |
Temperature Compensation | manual or automatic from –20.0 to 120.0 ºC (–4.0 to 248.0 ºF) | |
pH Electrode | HI 1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included) | |
Temperature Probe | HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included) | |
Logging | log on demand, 500 samples | |
PC Connection | opto-isolated USB with optional HI 92000 software | |
Input Impedance | 1012 Ohms | |
Power supply | 1.5V AAA (3) / approximately 200 hours of continuous use without backlight (50 hours with backlight). User selectable auto-off (5, 10, 20, 60 minutes or can be disabled) | |
Environment | 0 to 50°C (32 to 122°F); RH max 100% | |
Dimensions / Weight | 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) / 300 g (10.6 oz.) |