Features
• More precise, better accuracy than other water content analysis methods
• Measures 1ppm to 5%
• Low sample volume and preparation is easy
• Can be used for liquids or solids*
• Specific to water – independent of presence of volatile substances
• Closed reagent handling system with integrated diaphragm air pump maintains a dry environment
• Easily transfer methods and results (of drift analysis or titrations) to PC via the USB port
• Choose from diaphragm or diaphragm-less generator cells, depending on the specific application
• Compact shape will fit on any laboratory bench (not composed of many modules that can take up space)
Introducing the newest addition to Hanna’s family of Titration Systems: the HI 904 Coulometric Karl Fischer Titrator. The HI 904 excels at determining water content in
extremely small concentrations (1 ppm to 5%) and requires no titrant, instead using a generator electrode.
A pulsed DC current is applied to the generator electrode and results in oxidation of free iodide to iodine (the titrant) at the platinum anode. Alcohol, sulfur dioxide and base
(pyridine or imidazole) present in the reagents react to form a salt that is oxidized by the generated iodine. This reaction consumes water present in the cell in a 1:1 ratio
(iodine:water). Once all of the water is consumed, the excess iodine is detected using a bilvoltammetric detector electrode and signals the end of the titration. The result is
calculated from the amount of current applied to complete the reaction and the length of time that the generator electrode is active (A•s, or Coulombs).
Manual: Download
| Range | 1 ppm to 5% | |
| Resolution | 1 ppm (0.0001%) | |
| Accuracy | 1% | |
| Result Units | %, ppm, ppt, mg/g, µg/g, mg, µg, mg/mL, µg/mL, mg/pc, µg/pc | |
| Sample Type | Liquid or Solid* (external diss./extract.) | |
| Titration Vessel | Operating volume between 100-200 mL | |
| Reagent Handling System | Sealed system with intergrated diaphragm air pump and beaker adapter | |
| Generator Cell | Configuration | Fritted or Fritless (w/ or w/o diaphragm) |
| Generator Cell | Dosing | 50-400 mA pulsed DC current |
| Determination | Pre Titration Conditioning | Automatic |
| Determination | Background Drift Connection | Automatic; User Selectable Value |
| Determination | Endpoint Criteria | Fixed mV persistence, relative drift stop, or absolute drift stop |
| Determination | Dosing | Dynamic |
| Determination | Result Statistic | Mean, Standard Deviation |
| Electrode | Type/Connection | Dual patinum pin, polarization electrode / BNC |
| Electrode | Polarization Current | 1, 2, 5,10,15, 20, 30 or 40 µA |
| Electrode | Voltage Range | 2 mV to 1000 mV |
| Electrode | Voltage Resolution | 0.1 mV |
| Electrode | Accuracy (@25°C/77°C) | ±0.1 mV |
| Graphic Display | 5.7 (320 x 240 pixel) color LCD | |
| Titration Methods | Additional Specification | Up to 100 (standard and user) |
| Data Storage | Up to 100 titration and drift rate reports can be stored |
BL983313-1 EC Mini Controller, 0 to 1999 µS/cm, 230V
BL983320-1 EC Mini Controller 0 to 199.9 µS/cm, 230V
เครื่องวัดปริมาณคลอรีนอิสระ รุ่น HI701
เครื่องควบคุมค่าความนำไฟฟ้า
HI771 Checker HC ® - Chlorine, Ultra-High Range
BL983329-1 TDS Mini Controller 0.0 to 999 mg/L (ppm) - 230V
HI70031C - EC 1413 µS/cm@25°C Zert. - 25x20ml
HI770 Checker HC ® - Silica, HR
HI701 Checker HC ® - Free Chlorine
HI711 Checker HC ® - Total Chlorine
HI775 Checker HC ® - Alkalinity in fresh water (dKH)
HI706 Checker HC ® - Phosphorous, HR 