Both electrode and transmitter compatible inputs accepted
- Selectable manual ON, OFF and automatic dosing control with indicator
- Built-in auto-diagnostic function for offset and slope
- Both 4-20 and 0-20 mA output user selectable, all in one instrument
- Backlit LCD
- Transparent splash-proof cover included
- Operational mode LED indicators
HI 8931 is a panel mounted conductivity controller designed for simplicity of use. For in-line applications, use the HI 7635 probe, while for tanks the HI 7638 with external threads is recommended. These probes are provided with a built-in NTC sensor for temperature compensated conductivity measurements.
HI 8931 also features a direct connection up to 20 m (67′), without needing to amplify the signal to the conductivity probe.
Using the HI 8931 in conjunction with a 4-20 mA output transmitter (HI 8936 or HI 8936L series) will assure a strong, interference free signal at distances up to 300 meters (1000′).
Order Information:
The HI 8931 series is supplied with mounting brackets and instructions.
Manual: Download
Specification :
| Range | 0.00 to 19.99 mS/cm | |
| Resolution | 0.01 mS/cm | |
| Accuracy @ 20 °C | ±2% F.S. (excluding probe error) | |
| Input from Transmitter | HI 8936B / BL | |
| Temperature Compensation |
automatic, 0 to 60°C with ß=2%/°C; see also transmitter HI 8936 | |
| Inputs | DIN (probe) or 4-20 mA (transmitter) | |
| Conductivity Probe | HI 7635 for in-line applications or HI 3001D for flow-thru (not included) | |
| Calibration | manual, two point, through offset and slope trimmers | |
| Recorder Output | 0 to 20 mA or 4 to 20 mA (isolated) | |
| Setpoint and Alarm Relay |
1, Isolated, 2A, max. 240V, resistive load, 1,000,000 strokes | |
| Setpoint Range | 0.00 to 19.99 mS/cm | |
| Alarm Range | 0.00 mS and 10.00 mS | |
| Dosing Control | OFF/AUTO/ON with selection switch | |
| Over Dosing Control | adjustable, from 5 min to 60 min with knob or disable by wire strap – on rear panel | |
| Backlight | continuous on | |
| Power Supply | 115 VAC ±10% or 230 VAC ±10%; 50/60 Hz | |
| Enclosure | flame retardant ABS body and front panel; transparent splash-proof front cover | |
| Environment | -10 to 50°C (14 to 122°F); RH max 95% non-condensing | |
| Panel Cutout | 141 x 69 mm (5.6 x 2.7″) | |
| Weight | 1 kg (2.2 lbs.) |
สารเคมีสำหรับวัดค่าซิลิกา ช่วงสูง (HI96770-01)
เครื่องวัดปริมาณโครเมี่ยม ช่วงสูง รุ่น HI723
เครื่องวัดค่าออกซิเจนที่ละลายในน้ำ รุ่น HI5421
HI70000P - RfE - Standard Anwendung - 25x20ml
HI7036L - 12.41 g/L (ppt) TDS @25°C - 500ml
HI8931BN Conductivity Controller (0.01mS/cm resolution) with Input from Probe or Transmitter
HI93721-01 Iron HR - Reagents -100 Tests
เครื่องวัดปริมาณฟอสเฟต ช่วงสูง รุ่น HI717
HI7034L - EC 80000 µS/cm@25°C - 500ml
HI93704-01 Hydrazine - Reagents - 100 Tests
เครื่องวัดค่า pH/EC/TDS/Temp แบบพกพาสะดวก รุ่น HI98131
HI60004-02 - 4.010 pH@25°C - MQ - 25x20ml
HI38067-100 - Reagents for CTK Silica HR
HI93748-01 Manganese LR - Reagents - 50 Tests
HI7609829-2 - Dissolved Oxygen Sensor for HI9829 Multiparameter
HI7074L - RfE - Anorganische Substanzen - 500ml
เครื่องวัดความหวาน (น้ำตาลอินเวิร์ต) แบบภาคสนาม รุ่น HI96804
บีกเกอร์พลาสติก ขนาด 170 ml จำนวน 6 ชิ้น (HI740224)
Reagents for HI 701 (Free Chlorine), 25 Tests
เครื่องวัดคุณภาพน้ำ รุ่น HI5222 (pH/ISE/ORP พร้อมโหมด CAL Check™)
HI98127 เครื่องวัดค่า pH Meter แบบปากกาจาก Hanna
Calibration Standard HI 706 Checker HC ®
สารละลายมาตรฐานสำหรับสอบเทียบค่ากรด-ด่าง 9.18 (HI7009/1G)
HI6074 - 7.400 pH@25°C - MQ - 500ml
HI93740-01 Nickel LR - Reagents - 50 Tests
เครื่องวัดคุณภาพน้ำดีและน้ำเสีย แบบหลายพารามิเตอร์ รวมถึงค่า pH รุ่น HI83300-02
HI1292D - pH Electrode (Soil)
เครื่องวัดคุณภาพน้ำเพาะเลี้ยงสัตว์น้ำ แบบหลายพารามิเตอร์ รวมถึงค่า pH รุ่น HI83303-02
BL983321-1 TDS Mini Controller 0.00 to 19.99 mg/L (ppm) - 230V 