Fluoride is one of the very few chemicals that have been shown to cause significant effects in people through drinking-water. Fluoride has beneficial effects on teeth at low concentrations in drinking-water, but excessive exposure to fluoride in drinking-water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.
Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities.
A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.
The HI 739 Checker®HC is simple to use. In one vial add 2 ml of Reagent A and 8 ml of Reagent B; gently invert 5 times, and wait 1 minute, then zero the instrument with the vial. After zeroing, remove the vial and add 1 ml of sample, gently invert 5 times, wait 1 minute, then insert the cuvette into the HI 739 Checker®HC and press the read button for results.
Manual: Download
Specification :
| Range | 0.0 to 20.0 ppm | |
| Resolution | 0.1 ppm | |
| Accuracy @ 25°C | ±0.5 ppm ± 5% of reading | |
| Light Source | LED @ 575 nm | |
| Light Detector | silicon photocell | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
| Battery Type | (1) 1.5V AAA | |
| Auto-off | after two minutes of non-use and ten seconds after reading | |
| Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) | |
| Weight | 64 g (2.25 oz.) | |
| Method | adaptation of SPADNS method |
HI5005 - 5.00 pH@25°C - TQ - 500ml
HI775 Checker HC ® - Alkalinity in fresh water (dKH)
ซัลไฟด์สารต้านอนุมูลอิสระบัฟเฟอร์
เครื่องควบคุมค่าความนำไฟฟ้า
HI93752-01 Calcium and Magnesium HR, Oxalate (Ca) and Calmagite (Mg) (100 Tests)
HI701 Checker HC ® - Free Chlorine
HI705 Checker HC ® - Silica, LR
HI764 Checker HC ® - Nitrite, ULR
BL983315-1 TDS Mini Controller 0.0 to 199.9 mg/L (ppm) - 230V
HI5001 - 1.00 pH@25°C - TQ - 500ml
HI713 Checker HC ® - Phosphate, LR
HI70010P - 10.01 pH@25°C - SQ - 25x20ml
สารละลายมาตรฐานความขุ่น 20 NTU
HI768L Pt100-Type, 4-Wire Air /Liquid
HI7039L - EC 5000 µS/cm@25°C - 500ml
HI7021L - 240mV ORP Test Solution - 500ml
น้ำยามาตรฐานสอบเทียบ
HI706 Checker HC ® - Phosphorous, HR
HI763100 Digital conductivity electrode - 4 ring, platinum (edge)
HI1005 - pH Electrode, Flow-thru Monitoring for PCA
HI7022L - 470mV ORP Test Solution - 500ml
Multiparameter Benchtop Photometer and pH meter
HI70004C - 4.01 pH@25°C - SQ Zert. - 25x20ml
เครื่องวัดค่าเหล็ก รุ่น HI721
เครื่องวัดปริมาณโครเมี่ยม ช่วงสูง รุ่น HI723 