AmpHel ORP electrode with platinum pin, PTFE junction and 5 m cable.
- Strong signal up to 75 meters (246’)
- Low noise coaxial cables are no longer required
- Measurements in unclean samples and high humidity conditions
- Models with external replaceable battery, for longer electrode life
- Glass sensor for specific applications
Due to the high resistance of the glass membrane, conventional electrodes require a high impedance measurement system. Inadequate insulation of the connectors and cables result in erroneous readings due to leakage or noise. For conventional electrodes, the lead is therefore limited to typically less than 15-20 meters. HANNA AmpHel® electrodes incorporate a miniaturized amplifier which resolves most of the problems associated with high impedance signals. The amplifier circuitry is located right on top of the electrode and is completely sealed. As a result, a strong, low impedance signal is emitted and ordinary connectors with long unshielded cables can be used. This breakthrough technology provides a stable signal for industrial monitoring as well as a major saving in low noise coaxial cable costs. In some cases, the need for a transmitter is also eliminated, resulting in further cost reductions.
For those applications that have been proven particularly hostile to electrodes, HANNA has developed four types of specialized glass. First is an extremely durable sensor glass for general purpose and industrial use. This glass can withstand the stress of daily use. The remaining types of electrode glass allow continuous monitoring in highly acidic solutions containing fluoride ions, as well as high or low temperature process streams, without significantly reducing the useful life of the electrode.
Electrode body material is glass or PEI, while the junction is cloth or PTFE.
Specification :
| Body | PEI | |
| Junction | PTFE | |
| Electrolyte | gel | |
| Glass Type | platinum | |
| Temperature | -5 to 80°C | |
| Max Pressure | 3 bar (43.5 psi) | |
| Connection | BNC | |
| Cable | 5 m | |
| Battery | internal |
Reagents for HI 761 Checker HC ®, 25 Tests
HI903 Karl Fischer Volumetric Titrator - 100ppm to 100%
HI76409A/P DO Membrane for probe HI 76409 (5 pcs)
HI931001 pH and mV Precision Simulator (BNC)
HI5412 - Reference Electrode, Banana
HI7075 Electrode filling solution 1.7M KNO3 + 0.7M KCl, 4 x 30 ml
HI93738-01 Chlorine Dioxide - Reagents-Kit - 100 Tests
HI740224 - 170 ml plastic beaker (6 pcs)
HI70640L - RfE - Milch - 500ml
HI5003 - 3.00 pH@25°C - TQ - 500ml
HI93712-01 Aluminium - Reagents - 100 Tests
หัววัดค่าการนำไฟฟ้า/ของแข็งที่ละลายในน้ำ แบบ Four ring รุ่น HI76313 (Platinum)
HI3887 CTK pH & Free Chlorine
HI7022L - 470mV ORP Test Solution - 500ml
HI98183 pH / ORP / °C Meter + PC Interface, Waterproof
HI3002 - Submersion Conductivity Process Probe 