AmpHel general purpose pH electrode with PEI body, PTFE junction and 5 m cable.
- Strong signal up to 75 meters (246’)
- Low noise coaxial cables are no longer required
- Measurements in unclean samples and high humidity conditions
- Models with external replaceable battery, for longer electrode life
- Glass sensor for specific applications
Due to the high resistance of the glass membrane, conventional electrodes require a high impedance measurement system. Inadequate insulation of the connectors and cables result in erroneous readings due to leakage or noise. For conventional electrodes, the lead is therefore limited to typically less than 15-20 meters. HANNA AmpHel® electrodes incorporate a miniaturized amplifier which resolves most of the problems associated with high impedance signals. The amplifier circuitry is located right on top of the electrode and is completely sealed. As a result, a strong, low impedance signal is emitted and ordinary connectors with long unshielded cables can be used. This breakthrough technology provides a stable signal for industrial monitoring as well as a major saving in low noise coaxial cable costs. In some cases, the need for a transmitter is also eliminated, resulting in further cost reductions.
For those applications that have been proven particularly hostile to electrodes, HANNA has developed four types of specialized glass. First is an extremely durable sensor glass for general purpose and industrial use. This glass can withstand the stress of daily use. The remaining types of electrode glass allow continuous monitoring in highly acidic solutions containing fluoride ions, as well as high or low temperature process streams, without significantly reducing the useful life of the electrode.
Electrode body material is glass or PEI, while the junction is cloth or PTFE.
Specification :
| Body | PEI | |
| Junction | PTFE | |
| Electrolyte | polymer | |
| Glass Type | general purpose | |
| Temperature | -5 to 80°C | |
| Max Pressure | 3 bar (43.5 psi) | |
| Connection | BNC | |
| Cable | 5 m | |
| Battery | internal |
BL983314-1 Resistivity Mini Controller, 0.00 to 19.90 MΩ/cm - 230V
HI1292D - pH Electrode (Soil)
HI5002 - 2.00 pH@25°C - TQ - 500ml
HI93707-01 Nitrite LR - Reagents - 100 Tests
เครื่องวัดปริมาณไนไตรท์ ช่วงสูง ในตัวอย่างน้ำ รุ่น HI708
HI5522 Research Grade pH/ORP/ISE and EC/TDS/Salinity/Resistivity Meter with CAL Check™
HI3822 CTK Sulfite
BL983322-1 EC Mini Controller, 0 to 19.99 µS/cm, 230V
BL983315-1 TDS Mini Controller 0.0 to 199.9 mg/L (ppm) - 230V
BL983321-1 TDS Mini Controller 0.00 to 19.99 mg/L (ppm) - 230V
Reagents for HI 764 Checker HC ®, 25 Tests
HI70480 Free-chlorine reagent kit for PCA Series
HI5007 - 7.01 pH@25°C - TQ - 500ml
เครื่องวัดปริมาณโบรมีน ในตัวอย่างน้ำ รุ่น HI716
HI7042S Refilling Solution for Galvanic Probe, 30ml
HI93703-0 AMCO-AEPA-1 Calibration Solution at 0 FTU, 30 ml
HI98309 UPW - Ultra Pure Water Tester - Conductivity (up to 1.999 µS/cm)
HI3811 CTK Alkalinity
เครื่องวัดปริมาณฟอสเฟต ช่วงสูง รุ่น HI717
BL983329-1 TDS Mini Controller 0.0 to 999 mg/L (ppm) - 230V
BL983317-1 EC Mini Controller upto 10.00 mS/cm, 230V
HI727 Checker HC ® - Color of Water
HI706 Checker HC ® - Phosphorous, HR
เครื่องควบคุมค่าความนำไฟฟ้า
HI62911D - pH/°C Electrode
Reagents for HI 755 Checker HC ®, 25 Tests
BL983320-1 EC Mini Controller 0 to 199.9 µS/cm, 230V
BL931700-1 pH Mini Controller - 4 - 20mA output - 220V 