Chemical Oxygen Demand Portable Photometer – HI97106
HI97106 is a waterproof portable photometer that benefits from Hanna’s years of experience as a manufacturer of analytical instruments. It is a compact and versatile device designed to accurately determine chemical oxygen demand. The photometer has an advanced optical system that uses a Light Emitting Diode and a narrow band interference filter for accurate, repeatable readings. The optical system is sealed from outside dust, dirt, and water.
The meter uses an exclusive positive-locking system to ensure that the vials are placed into the holder in the same position every time. With the CAL Check™ functionality, users are able to validate the performance of the instrument at any time. Hanna Instruments CAL Check cuvettes are certified against NIST‑traceable reference instrument(s). The built-in tutorial mode guides users step by step through the measurement process. The tutorial mode includes all steps required for sample preparation, the required reagents, and quantities.
Suitable for bench measurements, the photometer features :
– Sophisticated optical system
– Meter validation using certified CAL Check cuvettes
– Tutorial mode guides the user step‑by‑step
– Auto logging
– Waterproof IP67 floating case

Manual : Downloads
Specification :
| SKU | HI97106 |
| Product Name | Chemical Oxygen Demand Portable Photometer |
| Chemical Oxygen Demand LR Range | 0 to 150 mg/L (as O₂) |
| Resolution | 1 mg/L |
| Accuracy | ±5 mg/L or ±4 % of reading at 25 °C, whichever is greater |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 420 nm |
| Chemical Oxygen Demand MR Range | 0 to 1500 mg/L (as O₂) |
| Resolution | 1 mg/L |
| Accuracy | ±15 mg/L or ±4 % of reading at 25 °C, whichever is greater |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Chemical Oxygen Demand HR Range | 0 to 15000 mg/L (as O₂) |
| Resolution | 1 mg/L |
| Accuracy | ±150 mg/L or ±2 % of reading at 25 °C, whichever is greater |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Chemical Oxygen Demand UHR Range | 0 to 60.0 g/L (as O₂) |
| Resolution | 0.1 g/L |
| Accuracy | ±0.5 g/L ±3 % of reading at 25 °C |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Measurement system Light source | LED |
| Bandpass filter | wavelength |
| Light detector | silicon photocell |
| Cuvette Type | round, 16 mm diameter |
| Photometer Specifications Auto logging | 200 readings |
| Display | 128 x 64 px B/W LCD with backlight |
| Auto-off | After 15 minutes of inactivity (after 30 minutes of inactivity if a Zero has been done but not a Read) |
| Battery type / Life | 1.5 V AA alkaline (3 pcs.) / > 10000 measurements (without backlight) |
| Environment | 0 to 50 °C ; 0 to 100 % RH, non-serviceable |
| Dimensions | 142.5 x 102.5 x 50.5 mm |
| Weight | 380 g with batteries |
เครื่องวัดปริมาณคลอรีนรวม รุ่น HI711
เครื่องวัดคลอรีน
เครื่องวัดปริมาณโบรมีน ในตัวอย่างน้ำ รุ่น HI716
เครื่องวัดปริมาณโครเมี่ยม ช่วงสูง รุ่น HI723
เครื่องวัดสีในน้ำตัวอย่าง HI727
เครื่องวัดปริมาณฟอสเฟต ช่วงต่ำ รุ่น HI713
เครื่องวัดปริมาณคลอรีนอิสระ รุ่น HI701
เครื่องวัดปริมาณฟอสฟอรัส ช่วงสูง รุ่น HI706
HI775 Checker HC ® - Alkalinity in fresh water (dKH)
HI700 Checker HC ® - Ammonia, LR
เครื่องวัดปริมาณฟอสเฟต ช่วงสูง รุ่น HI717
เครื่องควบคุมค่าความนำไฟฟ้า
FC232D - Foodcare pH-Elektrode für HI 99161, DIN, 1 m Kabel (Fleisch)
HI5007 - 7.01 pH@25°C - TQ - 500ml
HI740217 Lab Safety Shield for COD Measurement
เครื่องวัดปริมาณไนไตรท์ ช่วงสูง ในตัวอย่างน้ำ รุ่น HI708 