HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer.
Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly.
Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
- Specially formulated for cleaning electrodes
- Air tight seal to ensure quality
- Expiration date and lot number
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.
Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI7061L cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.
Air tight bottle with tamper-proof seal
- Ensures quality and freshness of solution
Each bottle marked with lot number and expiration date.
- Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.
Hanna offers a complete line of cleaning solutions engineered for specific applications.
สารเคมีวัดค่าไนเตรต HI782-25 ยี่ห้อ HANNA สำหรับวัดน้ำในตู้เลี้ยงปลาทะเล
HI4014-01 0.1 M Potassium Standard
HI7091L - Reducing Pretreatment Solution, 500 ml
HI710006 Power Adapter, 230 Vac to 12 VDC, European Plug
HI70038P - 6.44 g/l (ppt) TDS@25°C - 25x20ml
HI7081L 30 g/L Na solution for Sodium ISE, 500 ml Bottle
HI7078 Electrolyte solution 4 x 30 ml
HI93723-01 Chromium VI HR - Reagents - 100 Tests
เครื่องวัดค่าเหล็ก รุ่น HI721
HI7036L - 12.41 g/L (ppt) TDS @25°C - 500ml
HI98129 COMBO Tester for pH/EC/TDS/C° up to 3999 µS, waterproof
HI935005 K-Type Handheld-Thermometer - 1-Channel
BL983322-1 EC Mini Controller, 0 to 19.99 µS/cm, 230V
HI93740-01 Nickel LR - Reagents - 50 Tests
HI4115 - Silver/Sulfide ISE, Solid-state Combination
HI766TR1 K-Type, Long Penetration Probe
HI7004L - 4.01 pH@25°C - SQ - 500ml
HI93738-01 Chlorine Dioxide - Reagents-Kit - 100 Tests
สารละลายมาตรฐานความขุ่น 20 NTU 