HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer.
Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly.
Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
- Specially formulated for cleaning electrodes
- Air tight seal to ensure quality
- Expiration date and lot number
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.
Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI7061L cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.
Air tight bottle with tamper-proof seal
- Ensures quality and freshness of solution
Each bottle marked with lot number and expiration date.
- Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.
Hanna offers a complete line of cleaning solutions engineered for specific applications.
HI5002 - 2.00 pH@25°C - TQ - 500ml
HI6074 - 7.400 pH@25°C - MQ - 500ml
เครื่องวัดปริมาณคลอรีนรวม รุ่น HI711
น้ำยามาตรฐานสอบเทียบ ค่ามาตรฐานความเค็ม
HI98128 pH/°C-Tester (0.01 pH resolution) - waterproof
เครื่องวัดปริมาณซิลิกา ช่วงต่ำ ในตัวอย่างน้ำ รุ่น HI705
น้ำยามาตรฐานสอบเทียบ
HI991301 Multiparameter pH/EC/TDS/°C - EC to 20.00 mS
HI38054 CTK Ozone
เครื่องวัดปริมาณไนเตรตในน้ำทะเลช่วงต่ำ รุ่น HI781
เครื่องวัดปริมาณแอมโมเนีย ช่วงต่ำ รุ่น HI700
HI710006 Power Adapter, 230 Vac to 12 VDC, European Plug
HI716 Checker HC ® - Bromine
HI5012 - 12.00 pH@25°C - TQ - 500ml
เครื่องวัดสีในน้ำตัวอย่าง HI727
HI931001 pH and mV Precision Simulator (BNC)
HI7006L - 6.86 pH@25°C - SQ - 500ml
HI98127 pH/°C-Tester (0.1 pH resolution) - waterproof
เครื่องวัดค่าเหล็ก รุ่น HI721
เครื่องวัดปริมาณความเป็นกรด-ด่าง ในน้ำทะเล รุ่น HI780
HI4014-01 0.1 M Potassium Standard
HI38067-100 - Reagents for CTK Silica HR
HI93717-01 Phosphate HR - Reagents - 100 Tests
HI6100405 - AmpHel Flat Tip Process pH Electrode
HI98121 COMBO pH/ORP/°C-Tester, waterproof 